Company
Products
Order
Service
Contact
Home
Service

RFT 350FA Operators Manual

  1. NOTICE
  2. Rotary Flow-Thru Process Technology
  1. RFT-350 Plater System Overview
  2. Installation of the RFT-350 Plater
  1. Setting and Leveling
  2. Waste Piping Connections
  3. DI Water Supply
  4. Compressed Air Connection
  5. Process Cooling Media
  6. Fume Exhaust
  7. Electrical Power
  1. NT-series Programmable Terminal
  1. RFT 350, Operator interface
  2. The RFT OPERATOR CONTROL PANEL
  3. OPERATOR INTERFACE SCREEN OPERATION OVERVIEW
  1. MAIN MENU SCREEN
  2. SUB-MENU SCREEN
  3. PROCESS PARAMETER SCREEN
  4. MONITOR SCREEN
  1. Setting Process Parameters
  1. RINSE 1, 2 & 3 process parameters
  1. Purge Time Setting
  2. Cycle Time Setting
  3. Canopy Rinse Setting
  4. Middle Stop Setting
  5. Rotation Count Setting
  6. Drain Location Setting
  7. Rinse vs. Process time efficiency
  1. Pretreatment Parameters
  1. Purge Time Setting
  2. Cycle Time Setting
  3. Rotation Count Setting
  1. Electroplating Process Parameters
    Nickel & Solder Plate Parameters
  1. Purge Time Setting
  2. Cycle Time Setting
  3. PUMP OUTPUT
  4. Rectifier Control by Amp Minute Setting
  5. Rotation Count Setting
  6. Cell Rotation Speed By AC Frequency Inverter
  1. Temperature Control
  1. TEMPERATURE CONTROL SETTING
  1. System Parameters
  1. Amperage Setting
  2. Rectifier Delay Setting
  3. Cell Delay Setting
  4. Plating Process Mode
  1. Auto Process Setup
  1. Auto Process Setting
  2. RECOMMENDED PROCESS SEQUENCE TIPS
  1. Operation of System
  1. Operating by Manual, Semi Auto, and Full Automation
  1. Manual Functions
  1. Manual Loading
  2. Semi-Automatic Unloading
  3. Cell Rotation
  4. Drain Location
  1. Semi-Automatic Operation
  2. Full Automatic Operation
  1. PAUSE / CONTINUE PANEL SWITCH
  2. ABORT PANEL SWITCH
  3. EMERGENCY STOP BUTTONS
  4. LOADING & FULL AUTOMATIC UNLOADING
  1. Manual Loading
  2. Balancing Work Load
  3. Unloading
  4. Manual Unload of the Cell Dome
  5. Full-Automatic Unloading
  1. Maintenance of the RFT-350FA Plater
  1. Cleaning
  2. Process Control
  3. Cathode Brush Contact Maintainance
  4. Unload Head Maintainance
  5. Maintenance Schedule
  1. Process Cell Drive motor AC Frequency Controller
  1. Definitions of SX Drive Group Parameters, Parameter Group Tables
  2. Operation of the Touchpad Control Panel
  3. Display Mode, Drive Mode
  4. Monitor Mode
  5. Programming Mode
  6. Inverter Trip Cause and Remedies
  7. Other Errors and Remedies
  8. Suggested Maintenance Procedures
  1. Omron CQM1 Controller
  1. Omron Controller Overview
  2. System Configuration
  3. CQM1 Features
  4. Components
  5. Indicators
  6. PLC Modes
  7. Spec and Memory
  8. EEPROM Memory
  9. Battery Replacement
  10. Operators Manual
  1. Omron Trouble Shooting Flow Charts
  1. Main Check
  2. Power Supply Check
  3. Fatal Error Check
  4. Non-fatal Error Check
  5. I/O Check
  6. Environmental Conditions Check
  1. Mechanical Drawings
  2. Electrical Drawings

 

-
Company
-
Products
-
Order
-
Service
-
Contact
-
Home


Copyright © 1997, 1998, 2001, 2002, 2003 Griego Electrochemical Technologies Corporation